Home / Case Studies
Case studiesEvidence. Not assumptions.
Anonymised results from homes on the monitoring platform. Sensors indicate conditions; whether a hazard exists is decided by an inspection.
Case studies at a glance
Case study A · 5 weeks
Treated, but not fixed.
1.00 → 4.38
Mould index (VTT, 0-6), living room
Mould was treated on all four walls before the sensors went in. Five weeks later the risk had risen in every room, because the moisture causing it had not changed.
Living room1.00 → 4.38
Child’s bedroom3.50 → 4.10
Kitchen3.50 → 3.65
Bathroom1.00 → 3.18
Case study B · 12 days
A healthy home, one hidden hazard.
13.9°C
Lowest kitchen reading
No mould growth indicated in any room. But a room’s daily mean stayed below 16°C for four days running: excess cold, one of the hazards Awaab’s Law phase 2 brings in.
- Mould growth indicated in 0 of 4 rooms
- Kitchen below 18°C for 244 hours
- 4 of 6 humidity recovery checks met
01 / Case study A in detail5 weeks of readings
Treated, but not fixed.
Mould was treated on all four walls before the sensors went in. The readings showed the treatment had not removed the cause.
4 of 4rooms where mould risk is holding or rising
77-92%of hours with the wall surface at or above 80% humidity
90 minmedian bathroom humidity recovery, against about 30 minutes
22alerts raised, two at emergency level
| Priority action | When |
|---|---|
| Inspect the child’s bedroom and kitchen walls | Now |
| Inspect the living room and bathroom walls | Now |
| Find why bathroom and kitchen humidity is slow to clear | Now |
| Find the cause of the overnight build-up in the child’s bedroom | Now |
| Track room humidity against the 57.4-59.8% line | Within weeks |
| Keep monitoring through the winter | Ongoing |
The next step
Let’s create healthier homes. Together.
Request an initial 30-minute executive conversation, see the platform, or discuss a pilot programme.